Jacuzzi J - 470 Manuel d'utilisateur Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 104
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
Page 16
J-400 Series
7.0 Power Requirements
Jacuzzi
®
spas are designed to provide optimum performance and
exibility of use when connected to their maximum electrical service.
They are congured at the factory. The most common electrical
connections are listed below:
All North American 60 Hz Models only: These models come set for
50A logic. If you prefer, your qualied technician can perform a logic
modication that allows the spas to operate on a different electrical
service (see table footnotes below).
North American J-460/J-465/J-470/J-480 Models (60 Hz)
Voltage: 240 VAC 240 VAC 240 VAC
Max. Current Draw: 23A 36A 45A
Frequency: 60 Hz 60 Hz 60 Hz
Number of Wires: 3 3 3
Circuit Breaker (2-Pole): 30A* 50A** 60A***
*
In 30A conguration, the heater will not operate while either jets
pump is running.
**
In 50A conguration, the heater will not operate while both jet
pumps are running. This is the factory setting.
***
In 60A conguration the heater will operate while both jet pumps
are running.
All Export 50 Hz Models: These models have two terminals
requiring 2 circuit breakers and only have one logic option available.
Export J-460/J-465/J-470/J-480 Models (50 Hz)
Main
Terminal Breaker*
Heater
Terminal Breaker**
Voltage: 230 VAC 230 VAC
Max. Current Draw: 16.6A 12A
Wattage 3.8 kW 2.6 kW
Frequency: 50 Hz 50 Hz
Number of Wires: 3 3
*
The main terminal breaker is solely for the pumps, circulation
pump, ozone, stereo option (if installed) and accessories.
**
The heater breaker is solely for the heater, to allow the heater to
operate while both jet pumps are running.
Note: Two breakers needed see Figure E page 14.
Vue de la page 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 103 104

Commentaires sur ces manuels

Pas de commentaire